The peculiarities of the Tuapse refinery installation of
primary oil refining ELOU-AVT-12 commissioned in
2013 were shown. The device is intended for
dehydration and desalting of oil. Analyzed: tube
furnace N-1001/1,2 for heating oil and oven N-
2001/1,2,3,4, for heating the distilled fuel oil. Tube
furnace ELOU is one of the main sources of air
pollution. We have performed quantitative chemical
analysis of gas emissions furnace ELOU AVT and
determined percentage of components O2, N2, CO in
the emissions. The content of carbon monoxide in
emissions was less than 0.05%, which corresponds to
the standards. The average nitrogen content is 80%,
which also corresponds to standard indicators
The power plant being investigated is Novocherkassk
State District Power Plant located in the settlement of
Donskoy, Rostov region. The power object is included
in the list of objects of the fuel and energy complex
subject to categorization and is defined as critically
important. The analyzed site is the "subsidiary farm",
which includes a chemical reagent warehouse and a
site for chemical water purification, where hazardous
substances are treated: sulfuric acid and technical
sodium hydroxide. The analysis of the main causes of
accidents at thermal power stations occurred during
processing, storage and transportation of hazardous
substances, and typical scenarios of possible accidents
at the chemical water treatment plant of thermal power
plants were considered